Table 2
Relative annual energy yields of bifacial modules with and without a reflecting foil between the cells compared to the monofacial reference module for three park configurations. The annual open field irradiance is given in column GHI, the diffuse percentage is given in column DHI.
Park design | Country | GCR | GHI [kWh/m2] | DHI | Transparent BF | BF with reflective mesh | Gain foil |
---|---|---|---|---|---|---|---|
East-west | NL | 90% | 1040 | 55% | +0.9% | +1.9% | +1.0% |
South | NL | 70% | 1040 | 55% | +2.0% | +3.4% | +1.4% |
South | ES | 60% | 1886 | 31% | +2.2% | +3.5% | +1.3% |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.