Table 2

Difference in Pmax (W) for the PM for the polycrystalline PV module (OP51) Before and After correction of the temperature according to the ECT procedure described here. The difference, Δ in W, is the Before correction value minus the After correction value, within brackets, in percentage, the difference divided by the Before correction value.

Irradiance (W/m2) Temperature

  15 (°C) 25 (°C) 50 (°C) 75 (°C)

  Pmax (W)
  Δ W (%) Δ W (%) Δ W (%) Δ W (%)
1100 0.30 (0.10) 0.40 (0.14) 0.60 (0.24) 0.70 (0.31)
1000 0.10 (−0.40) 0.00 (0.00) 0.10 (0.04) 0.20 (0.10)
800 0.70 (−0.33) 0.20 (−0.10) 0.80 (0.43) 1.70 (1.02)
600 0.90 (−0.56) 0.40 (−0.26) 0.80 (0.57) 2.10 (1.67)
400 0.30 (−0.28) 0.10 (0.10) 0.90 (0.96) 1.70 (2.02)
200 0.50 (−0.97) 0.20 (−0.40) 0.31 (0.69) 0.80 (1.98)
100 0.13 (−0.53) 0.02 (−0.08) 0.23 (1.07) 0.48 (2.51)