Issue |
EPJ Photovolt.
Volume 14, 2023
Special Issue on ‘Recent Advances in Photovoltaics 2022’, edited by Mohamed Amara, Thomas Fix, Jean-Paul Kleider, Judikaël Le Rouzo and Denis Mencaraglia
|
|
---|---|---|
Article Number | 25 | |
Number of page(s) | 7 | |
Section | Modules and Systems | |
DOI | https://doi.org/10.1051/epjpv/2023014 | |
Published online | 24 August 2023 |
https://doi.org/10.1051/epjpv/2023014
Regular Article
Analysis of the degradation of amorphous silicon mini-modules under a severe sequential UV/DH test
1
Univ Paris-Est Créteil, CERTES, IUT de Sénart-Fontainebleau, 36 rue Georges Charpak, 77127 Lieusaint, France
2
ICAM, site de Grand-Paris Sud, Carré Sénart, 34 Points de Vue, 77127 Lieusaint, France
3
SLITE-Source, 3 rue Léon Blum, 91120 Palaiseau, France
4
SOLEMS, 3 rue Léon Blum, 91120 Palaiseau, France
*e-mail: julia.vincent@icam.fr
Received:
27
January
2023
Received in final form:
9
May
2023
Accepted:
5
June
2023
Published online: 24 August 2023
This study presents the results of severe accelerated tests carried out on four encapsulated amorphous silicon (a-Si) mini-modules. All the a-Si mini-modules were exposed to a 85 °C and 85% relative humidity damp heat (DH) prolonged treatment for 5000 h representing five times the duration specified by the IEC 61215 standard for qualification tests. For two of the four mini-modules, the DH test was preceded by a severe UV preconditioning, by applying 30 times the dose of 15 kWh/m2 at a temperature of 50 °C as prescribed by the IEC 61215 standard, in order to enhance the degradation during the following DH test and to reduce the overall testing time. I–V curves were plotted with a time step of 100 h under standard test conditions (STC) using a class A solar simulator and a source meter in order to monitor the degradation throughout both the tests. A visual inspection with photographic capturing was also performed at each stage to detect the apparent defects. Corrosion observed after 2000 h owing to the ingress of humidity is explained here by two possible infiltration paths in the layers of the mini-modules. Delamination occurred after 5000 h for the PV mini-modules which underwent the extended DH test. After 5000 h of damp heat testing, the degradation of the maximal power (Pmax) was found to be slightly accelerated for the a-Si mini-modules that were previously exposed to a severe UV preconditioning, with a value reaching 80% of its initial value, whereas, for the others only subjected to the prolonged DH test, the maximal power remained above 80% of its initial value. In all cases, the mini-modules seemed highly reliable with no failure after 5000 h of accelerated testing, and, based on an equivalent time of 20 years for 1000 h of accelerated test, they would exhibit a limited degradation rate of 0.2%/year in outdoor field conditions.
Key words: Photovoltaic / amorphous silicon / mini-modules / accelerated test / corrosion
© J. Vincent et al., Published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.