Table 5

Module architecture energy and algorithm efficiency summary for full illumination, total shading and partial shading conditions during the route. The energy is indicated as a percentage of the maximum available energy during the entire route, and the efficiency of the P&O algorithm is evaluated under Tper=83 ms (12 Hz) and Vper = 4% of VMP-STC.

Fully illuminated Fully shaded Partially shadowed (total)
62.00% of time, 78.89% irradiation 7.20% of time, 0.94% irradiation 30.80% of time, 20.17% irradiation
Configuration Total Available Energy [Wh] Total P&O η [%] Energy fraction [%] P&O η [%] Energy fraction [%] P&O η [%] Energy fraction [%] P&O η [%]

SLM-V-Series 8.28 95.97% 85.84% 98.74% 0.08% 69.10% 14.08% 69.60%
SLM-H-Series 8.18 95.96% 86.86% 98.29% 0.08% 68.46% 13.06% 70.89%
SLM-V-TCT 8.77 96.62% 85.00% 98.61% 0.08% 64.32% 14.92% 82.41%
SLM-H-TCT 8.72 97.00% 85.06% 98.99% 0.08% 64.58% 14.86% 81.61%
6MM-V-Series 8.46 96.69% 84.27% 98.72% 0.08% 68.24% 15.63% 73.17%
6MM −H-Series 8.28 96.59% 85.27% 98.53% 0.09% 69.10% 14.64% 74.53%
6MM −V-TCT 8.95 96.57% 84.13% 98.68% 0.08% 66.85% 15.80% 79.19%
6MM −H-TCT 8.91 96.77% 84.45% 98.57% 0.08% 67.29% 15.46% 77.80%

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.