Table 1

Overview of the modules and experimental conditions in the indoor experiment and the outdoor experiment. The initial power deviation of all modules is given as a relative deviation from the nominal power. The injected current was defined relative to the nominal ISC (deviation between the two power classes < 1%).

Module designation Experiment Nominal power History Initial power deviation Temperature (Indoor experiment) Injected current
Ind_1_10C_1.0xIsc Indoor 340 W Power Plant –8.4% 10 (+2.6/–3.8) °C ISC, pulsed
Ind_2_11C_1.25xIsc Indoor 340 W Power Plant –8.5% 11 (+1.5/–4) °C 1.25 x ISC, pulsed
Ind_3_22C_0.5xIsc Indoor 340 W Power Plant –9.1% 22 (+/–2.5) °C 0.5 x ISC, pulsed
Ind_4_23C_0.5xIsc Indoor 335 W LeTID Test –6.4% 23 (+/–3) °C 0.5 x ISC, pulsed
Ind_5_21C_0.75xIsc Indoor 340 W Power Plant –9.1% 21 (+1.5/–2.5) °C 0.75 x ISC, pulsed
Ind_6_21C_1.0xIsc Indoor 340 W Power Plant –9.4% 21 (+5.5/–3.5) °C ISC, pulsed
Ind_7_21C_1.0xIsc Indoor 335 W LeTID Test –9.8% 21 (+/–3) °C ISC, pulsed
Ind_8_23C_1.0xIsc Indoor 340 W Power Plant –8.0% 23 (+4/–6.5) °C ISC, constant
Ind_9_20C_1.25xIsc Indoor 340 W Power Plant –9.4% 20 (+3/–2.5) °C 1.25 x ISC, pulsed
Ind_10_40C_1.0xIsc Indoor 340 W Power Plant –8.5% 40 (+1.5/–4.5) °C ISC, pulsed
 
Outd_1_Ref Outdoor 340 W Power Plant –7.7%
Outd_2_Ref Outdoor 340 W Power Plant –8.4%
Outd_3_1.0xIsc_p Outdoor 340 W Power Plant –9.5% ISC, pulsed
Outd_4_1.25xIsc_p Outdoor 340 W Power Plant –10.0% 1.25 ISC, pulsed
Outd_5_1.0xIsc_c Outdoor 335 W Power Plant –8.3% ISC, constant
Outd_6_1.25xIsc_c Outdoor 335 W Power Plant –8.4% 1.25 ISC, constant