Table 3

The recommendations from this study for HS test conditions in IEC TS 63126:2020.

Hot-spot endurance test Standard (IEC 61215:2021) Level 1 (70 °C < T98 ≤ 80 °C) Level 2 (80 °C < T98 ≤ 90 °C)
IEC TS 63126:2020* 55±15 °C 60±10 °C 70±10 °C
Proposal of this study 55±15 °C 75±10 °C 85±10 °C

*When IEC TS 63126:2020 was published, still IEC 61215-2:2016 was in action and module temperature of the HS test was 50±10 °C.