Table 2

The worst-case shading rates of the four selected cells for each module technology determined by following the IEC 61215-2:2021 and shortened procedures.

Module technology Worst-case shading rates of Cell-1,Cell-2, Cell-3 and Cell-4
IEC 61215-2:2021 procedure Shortened IEC 61215-2:2021 procedure
PERC Half-Cell 9% 10.5%
9% 9.9%
IBC Full-Cell 100% 100%
100% 100%
HJT Half-Cell 14% 11.8%
14% 12.3%
PERC Full-cell 8%, 8%, 10% and 15% 11.9%