Table 1

Details on the modules (and cell technology) used and the indoor and outdoor test conditions.

Module technology Indoor hot-spot endurance tests Outdoor tests (monitoring)
IEC 61215-2:2021 (55 °C, 5 h) + 5 h* IEC TS 63126:2020
Level 2 (75 °C**, 5 h) + 5 h*
BIPV*** BIPV*** & shadow mask
1 – PERC − Half-Cell
(20 cells/diode)
1 1 1 (Insulated) 1 (Insulated)
2 − IBC − Full-Cell
(104 cells, 3 dio des)
1 1 1 (Insulated) 1 (Insulated)
3 − HJT − Half-Cell
(20 cells/diode)
1 1 1 (Insulated) 1 (Insulated)
4 − PERC − Full-cell
(10 cells/diode + 20 cells/diode)
1 1 (Partially Ventilated) 1 (Partially Ventilated)

PERC: Passivated Emitter and Rear Contact, IBC: Interdigitated Back Contact, HJT: Heterojunction technology 

* Extended hot-spot test with a total duration of 10 h. 

** As stated in the text, the module temperature was considered to be 75 °C instead of 70 °C. 

*** The BIPV mounting configuration are indicated for each module technology.