Table 3

Part of the PM, for the polycrystalline PV module (OP51) measured with Apollo where correction of the temperature according to the ECT procedure described in IEC 60904-5 has been performed (Apollo ECT Δ) and not performed (Apollo before Δ) compared to the power measured with the Pasan IIIc solar simulator. The difference Δ in W is the Pasan IIIc value minus the Apollo value, within brackets, in percentage, the difference divided by the Apollo value.

Irradiance (W/m2) Temperature

  15 (°C) 25 (°C) 50 (°C) 75 (°C)

  Pmax (W)
  Apollo before
Δ W (%)
Apollo ECT
Δ W (%)
Apollo before
Δ W (%)
Apollo ECT
Δ W (%)
Apollo before
Δ W (%)
Apollo ECT
Δ W (%)
Apollo before
Δ W (%)
Apollo ECT
Δ W (%)
1100 0.80 (−0.27) 1.10 (−0.38) 0.50 (−0.18) 0.90 (−0.32) 0.10 (0.03) 0.50 (−0.20) 0.60 (0.27) 0.10 (−0.04)
1000 0.10 (−0.04) 0.00 (0.00) 0.00 (0.00) 0.00 (0.00) 0.10 (0.04) 0.00 (0.00) 0.20 (0.10) 0.00 (0.00)
800 1.10 (−0.51) 0.40 (−0.19) 0.50 (−0.24) 0.30 (−0.15) 0.90 (0.42) 0.10 (0.05) 2.10 (1.28) 0.40 (0.24)
600 0.80 (−0.50) 0.10 (0.06) 0.10 (0.07) 0.30 (0.20) 1.40 (0.87) 0.60 (0.43) 3.00 (2.45) 0.90 (0.73)
400 0.40 (0.38) 0.70 (0.66) 0.90 (0.88) 0.80 (0.78) 2.10 (1.97) 1.20 (1.31) 3.40 (4.20) 1.70 (2.10)
200 0.01 (0.02) 0.51 (0.99) 0.37 (0.74) 0.57 (1.15) 1.05 (2.03) 0.74 (1.68) 1.73 (4.46) 0.93 (2.40)
100 0.07 (−0.28) 0.06 (0.24) 0.08 (0.34) 0.10 (0.42) 0.44 (1.78) 0.21 (1.00) 0.79 (4.30) 0.31 (1.69)