Table 1

Technical parameters of the four photovoltaic modules in STC.

  KG200GT Q6LM.m MSX60 PW1650
Current at Pmax (Im) (A) 7.61 7.11 3.5 4.8
Voltage at Pmax (Vm) (V) 26.3 0.5113 17.1 34.4
Short-circuit current Isc (A) 8.21 7.6 3.8 5.1
Open-circuit voltage Voc (V) 32.9 0.6118 21.1 43.2
No-load voltage/temperature coefficient KV (V/K) −0.1230 −0.0037 −80 10−3 −0.158
Short circuit current/temperature coefficient KI (A/K) 0.0032 0.0005 0.003 0.00146
Number of cells connected in series Ns 54 1 36 72
Ideality factor a 1.3 1.2 1.3 1.0
Shunt resistance Rsh (Ω) 415.405 5.0001 304.833 2013.58
Series resistance Rs (Ω) 0.221 0.0012 0.2 0.72
Surface 1425 mm × 990 mm 156 mm× 156 mm  1105 mm× 502 mm  1237 mm × 1044 mm
Load Rm (Ω) 3.45 0.071 4.885 7.166