Technical parameters of the four photovoltaic modules in STC.
KG200GT | Q6LM.m | MSX60 | PW1650 | |
---|---|---|---|---|
Current at Pmax (Im) (A) | 7.61 | 7.11 | 3.5 | 4.8 |
Voltage at Pmax (Vm) (V) | 26.3 | 0.5113 | 17.1 | 34.4 |
Short-circuit current Isc (A) | 8.21 | 7.6 | 3.8 | 5.1 |
Open-circuit voltage Voc (V) | 32.9 | 0.6118 | 21.1 | 43.2 |
No-load voltage/temperature coefficient KV (V/K) | −0.1230 | −0.0037 | −80 10−3 | −0.158 |
Short circuit current/temperature coefficient KI (A/K) | 0.0032 | 0.0005 | 0.003 | 0.00146 |
Number of cells connected in series Ns | 54 | 1 | 36 | 72 |
Ideality factor a | 1.3 | 1.2 | 1.3 | 1.0 |
Shunt resistance Rsh (Ω) | 415.405 | 5.0001 | 304.833 | 2013.58 |
Series resistance Rs (Ω) | 0.221 | 0.0012 | 0.2 | 0.72 |
Surface | 1425 mm × 990 mm | 156 mm× 156 mm | 1105 mm× 502 mm | 1237 mm × 1044 mm |
Load Rm (Ω) | 3.45 | 0.071 | 4.885 | 7.166 |