1 Introduction

The greenhouse gas emissions occupy a major concern our societies are facing nowadays.

One of the crucial factors contributing to this problem are fossil fuels emissions. Thus, the substitution of these resources by renewable energies is a major challenge occupying the interest of governments at a worldwide level.

According to SolarPower Europe 2019, a 36% increasing in solar power plants installation has occurred between 2017 and 2018 at the European Union level1. Furthermore, the estimated growth in solar market by 2022 is around 40 GW. The price of solar power production is dropping rapidly nowadays allowing an important energy system shifting from conventional fossil fuels to clean energy in the upcoming years.

For identical PV installations in different geographical locations, power generation won't be the same. This is due to the difference in the solar irradiance flux reaching the PV modules, the atmospheric conditions, the environment of the installation and geometrical aspects. Thus, an adequate plane of array irradiance study must be performed considering all the mentioned parameters in order to have an accurate system's efficiency assessment.

In order to improve the operating performances of solar installations, high efficiency photovoltaic systems are under development. In fact, adding reflectors in front of the PV arrays contributes in increasing the incident irradiance on the modules and thus increasing the electrical production efficiency. For instance, some research studies about flat reflectors technologies with fixed and automated mirrors topologies are conducted [13]. One of the objectives of such studies aims to define adequate settings for PV-reflector systems with fixed inter-rows space as well as the impact of string mismatch of such systems [2]. According to [2], adding planar reflectors represents a low cost solution where during clear sky days, the produced energy can increase up to 35%. The evaluation of flat booster reflectors in various PV installations and different alternative arrangements was performed as well in [3]. For example, we can cite ALEPH project (Amelioration of photovoltaic efficiency) conducted in SIRTA [4] aiming to increase the system's yield by adding inter-row planar reflectors. Furthermore, an industrial PV system equipped with planar reflectors was developed by TENKSOLAR, Bloomington, United States [5] focusing on the importance of flat large area reflectors concept. Other studies are performed also describing the advantages of the flat reflectors by increasing the incident solar flux on the solar thermal systems. In Sweden, the annual irradiance can be increased between 8% and 17% by adding flat reflectors according to a study conducted considering the evenly distributed radiation [6]. Moreover, according to a research performed in different locations in USA the irradiance can be increased up to 9% for an optimized fixed PV-reflector configuration [7].

One advantage of a planar reflector PV system is that it represents a low concentration technology compared to the parabolic concentrators. Therefore, with flat reflectors the temperature negative effect is not much significant, thus, a cooling procedure is not required which contributes in reducing the system's cost [8]. Furthermore, for PV-reflector system, we do not need a precise sun tracking equipment, which is not the case of CPV technology requiring high accuracy and reliability for tracking systems, automatically leading to an increased cost.

The main objective of this work is elaborating a POA irradiance estimation model for a PV system equipped with flat reflectors. The system's efficiency is investigated within the frame of geometrical optimization case studies relying on two parameters: the length ratio between the reflector and the PV module and the architecture variation frequency. In order to meet the highest performances according to the solar profile the optimization results were retrieved. For that purpose, the case studies relied on the climatic data issued from SIRTA [9], [10] at Palaiseau, France.

2 Methodology

2.1 Modelling methodology

The solar radiation received by a tilted surface with respect to the horizontal surface is composed of three elements:

  • The direct solar radiation following a straight trajectory from the sun to the surface of earth.

  • The diffuse solar radiation scattered in the atmosphere and reaching the surface of the earth.

  • The reflected radiation coming from the ground and the surrounding area (Fig. 1a).

  • In case of a system equipped with flat reflector, the direct and diffuse irradiances reaching the mirror's surface to be then reflected on the PV module will be added (Fig. 1b).

A Matlab POA irradiance estimation model was developed using the measured irradiances data from SIRTA (Site Instrumental de Recherche par Télédétection Atmosphérique) observatory [9]: GHI, DHI and BNI (Fig. 2) and the irradiance reflected by the mirrors was computed as well. In addition, other parameters were considered such as the solar angles (θza, θa, and AOI), the geometrical position, orientation and dimensioning of the PV-Reflector architecture as well as ground and mirror's reflection properties.

thumbnail Fig. 1

Irradiances characterizing a classical PV system architecture (a) and a PV-reflector system architecture (b).

thumbnail Fig. 2

Direct, diffuse and global irradiances measurement sensors, SIRTA observatory, which are part of the PAL station of the Baseline Surface Radiation Network (BSRN, https://bsrn.awi.de/).

2.2 Modelling equations

The analytical model developed through this work was based on a detailed study of solar radiation estimation [12] (Solar Engineering of thermal processes textbook). A study describing feasibility cases of using flat booster reflectors in PV installations was considered as well [3].

Angle of incidence:(1)

View factor from the reflector to the PV module:(2)

View factor from the PV module to the reflector:(3)

2.2.1 Computing the plane of array irradiance considering a classical PV installation without mirrors

The plane of array irradiance calculation is based on two main simplifications: the sky diffuse irradiance is considered isotropic (uniform in all orientations) and the ground surface is considered Lambertian (its reflectance is the same regardless of the view angle).(4)

2.2.2 Computing the plane of array irradiance considering a PV installation equipped with flat reflectors

Ground reflected incident solar radiation:(5)

Direct reflected beam irradiance: direct irradiance reaching the mirrors to be reflected on the PV modules:(6)

Diffuse reflected solar radiation: diffuse irradiance received by the mirrors to be reflected on the PV modules:

(7)

General equation of POA irradiance with reflectors according to the illumination height on the PV module as well as the AOI:(8)

In order to establish an accurate estimation of the plane of array irradiance with the presence of reflectors, several particular cases need to be addressed. These cases are considered according to different impacts that the reflectors could have on a PV panel and thus to the effective POA irradiance received by it:

  • Case 1: The reflected irradiance from the mirror covers the highest level of the PV module length (as shown in Fig. 3a) or exceeds it. In this case, the equation (8) keeps all the terms.

  • Case 2: The reflected irradiance from the mirror covers an inferior level of the PV module length (Fig. 3b), and thus we consider that DRBI = 0. In this case the irradiance mismatch effect is taken into consideration and thus the activation of bypass diodes wasn't neglected. Therefore, the direct irradiance of the reflected beams is not considered here.

  • Case 3: Period where the reflector is totally or partially shading the PV module: Only the diffuse irradiance can be considered in this case (Fig. 3c). No direct irradiance component is considered. Therefore, in this case the direct irradiance (BNI) reaching the planar reflectors or the PV modules is not taken into consideration.

  • Annual gain in POA irradiance added by the reflectors is calculated as follows:

(9)
  • Monthly gain in POA irradiance added by the reflectors:

(10)With θtiltoptimum. θRoptimum are respectively the optimal PV module and reflector inclination angles where a maximum POA irradiance is achieved each month.

thumbnail Fig. 3

Estimation of the plane of array irradiance according to the reflector: reflected irradiance reaching the highest level (a), reflected irradiance is below the highest level of the PV module (b) and causing total or partial shading on the PV module (c).

3 Experimental validation

The model was validated experimentally with and without reflectors using the plane of array irradiance measurements from the SIRTA test bench [4,9,10], during a campaign where measurements were recorded over 13 months (June 2017–June 2018). Flat reflectors were installed between July and October 2017 (Fig. 4) and thus two periods are considered. For PV-reflector installations, it's always desirable to have overhanging on the right and left of the PV modules on the edges in order to limit mismatch effects. In the experimental PV installation performed, the Panasonic HIT module was considered for the study. Thus, there were a large overhanging from the west of the module without a considerable one on the East side as illustrated in Figure 4. On the other hand, in the plane of array estimation model developed, infinite mirrors rows were considered. Thus, the estimation model does not consider the edge effect. We performed irradiance measurements in the plane of array using a solar pyranometer (Hukseflux SR01) and reference PV cells (SOLEMS RG100) installed at the top of the plane of array (Fig. 4). For this work, hourly averages from one-minute data are used.

thumbnail Fig. 4

Characterization test bench equipped with sensors and flat reflectors, SIRTA observatory.

3.1 Evaluation indicators

In the experimental validation process, we calculated error indicators in order to compare our simulation results with measurements. The indicators used are MBE, RMBE, MAE and RMAE.

(11)(12) (13) (14)

3.2 Experimental validation for the installation without reflectors

In this part, a comparison between the modelled and measured POA irradiance was performed in the absence of flat reflectors. As shown in Figure 5, the POA modelled irradiance was compared to the POA measured irradiance for the period between October 13th 2017 and June 8th 2018. The error indicators show a RMAE and RMBE values of 6% and 0.6%, respectively. Notice that the sensors for GHI, DHI and BHI are located 700 m away from the POA irradiance measurements, therefore a certain part of the error estimation could be caused by the distance between the sensors. However, this is estimated small (<3% and <15 W/m2, study not shown here) as hourly averages are used in this work.

thumbnail Fig. 5

Comparison between the measured and modelled POA irradiance over the period from October 13th 2017 to June 8th 2018: Installation without flat reflectors.

3.3 Experimental validation for the installation with reflectors

In this part, a comparison between the modelled and measured POA irradiance was performed in the presence of mirrors during the campaign conducted between July and October 2017 (Fig. 4). The experimental PV installation setup was composed of five PV modules from different technologies with a 26.7° tilt angle to the horizontal plane. The Panasonic HIT N240 module was considered in our studies. Thus, the POA irradiance measurements were retrieved out of SR01 and RG100 sensors installed at the upper level of the Panasonic PV array. The mirrors were placed between July 25th and October 12th 2017 with a 14.6° inclination to the horizontal plane.

Results are shown in Figure 6, and the obtained error indicators were 7% and 0.9% for RMAE and RMBE respectively, showing consistency with the errors obtained without reflectors, as exposed above. In all cases the bias is small, less than 1%, which is relevant for the validity of the optimization work that is presented in the following sections.

thumbnail Fig. 6

POA measured vs. POA modelled irradiances (September 2017 to October 2017).

3.4 Comparison between the plane of array irradiance with and without reflectors

Considering the experimental setup parameters performed in SIRTA, in this section we compared the POA irradiance modelled with reflectors to the modelled POA irradiance without reflectors. Thus, according to our platform, in this phase we used fixed parameters for the tilt angles of the PV array and the reflector as well as a mirror's reflectivity: θtilt = 26.7°, θR = 14.6°, LR = 0.96 m, LPV = 1.58 m and R is taken constant at 0.8 (as obtained from reflectivity measurements done in laboratory, not shown here).

Figure 7 shows the simulation results of the comparison between the POA irradiance with vs without reflectors with the same parameters used in the experimental test bench (Fig. 4). The GA added by the mirrors is of 2.26% over the 13 months between June 2017 and June 2018. Thus, it's obvious that in this case, the reflectors effect isn't much significant which is normal because the architecture studied here isn't optimized for a maximum efficiency. The main experimental objective was to evaluate the effect of non-uniform illumination added by the reflectors as published in a previous work [4] as well as to validate a Matlab/Simulink model we performed for electric power output prediction in case of non-uniform illumination [11]. Therefore, in order to achieve the maximum POA irradiance from the overall system leading to an efficient power generation, an optimization process is required. It is interesting to observe in the figure that there are three kinds of points that correspond to the three cases presented in Section 2.2. Case 1 would correspond to the points over the 1:1 line, for which there is a positive effect of the mirrors on the POA irradiance. Case 2 corresponds to the points on the 1:1 line, as the overexposure from the mirror do not reach the top of the panel length and thus no effect is counted. Finally, case 3 corresponds to the points for which the mirror has a negative effect, that is when the sun is behind the mirror and thus it blocks the direct component of the POA irradiance.

The following part describes a modelling optimization strategy conducted with the results achieved.

thumbnail Fig. 7

Comparison between the POA irradiance with and without reflector from 1st June 2017 to 8th of June 2018.

4 Optimization strategy and results

4.1 Strategy

In order to achieve higher efficiencies, an adequate PV-reflector geometry as well as appropriate reflector material must be studied. In this section, we focus on the PV module-reflector architecture geometry optimization for a maximum POA irradiance reaching the modules. For that purpose, we assumed at this level a fixed ground albedo and mirror's reflectivity coefficients (ρg= 0.2, R = 0.8). We conducted performance studies for a south oriented system in Palaiseau (France) over 13 months considering the measured GHI, BHI and DHI from SIRTA (Fig. 2). Our strategy relied on varying two major parameters affecting the plane of array irradiance: the mirror's length according to the PV module length (LR /LPV ), and the angular variation of the system (θtilt and θR variation) as illustrated in Figure 8. For the angular variation, we considered three possibilities: a monthly variation, a seasonal variation or a fixed architecture. Each geometrical optimization procedure will result with the optimum θtilt and θR for each month corresponding to the maximum GA issued from the overall system. Our optimization study relied on the particular period from June 2017 to June 2018 (Measurements and Simulation).

thumbnail Fig. 8

Experimental platform characterized by LR, LPV, θtilt and θR.

4.2 Optimization results of an installation without reflectors

The first step consisted on varying θtilt considering a conventional installation, without reflectors in order to find the optimal θtilt leading to the maximum POA irradiation for each month. Table 1 presents the results of this step.

As shown in Table 1, according to our analytical model, for a classic south oriented installation in Palaiseau, France the optimum tilt angle value varies between 21 and 30 degrees for the summer season when the sun elevation is high whereas a maximum of 6891.7 Wh/m2 is achieved in July. θtilt increases to reach a maximum of 63 degrees in winter when the sun is lower and we can notice the lowest E in December with 962.3 Wh/m2. During spring, an average tilt angle value can be adjusted between 28 and 34 degrees for a maximum POA incident irradiation.

Table 1

Optimal θtilt corresponding to the POA max of each month for a classical installation.

4.3 Optimization results of a PV-reflector installation

In the following parts, the POA irradiation modelled at the highest point of a photovoltaic array equipped with flat reflectors is considered for our optimization process. Thus, for different reflector's lengths, we varied the array tilt angle as well as the tilt of the reflectors and we concluded the best (θtilt ,θR ) combination in order to achieve a maximum POA irradiation.

First, we began by investigating our system's behavior when varying LR from LPV/2 to 10LPV as illustrated in Figure 9 and shown in Table 2. We repeated the same procedure for the monthly and seasonal varied as well as the fixed architectures. Our objective at this level is to find the reflector's length where GA begins to stabilize around a constant value. The results show that the gain increases significantly for the three cases between LPV/2 to 2LPV and continues increasing in a slower rate until reaching 8LPV where it stabilizes around 40%, 36% and 20% for the monthly, seasonal and fixed variation cases respectively. Nevertheless, other limitation constraints must be considered such as the space available for the installation as well as the inter-row distance in case of multiple rows PV installation. In the following parts only the cases of LPV/2, LPV and 2LPV will be considered for monthly angular variation.

thumbnail Fig. 9

GA variation according to the reflector's length for a monthly varied, seasonal varied and a fixed architecture.

Table 2

GA variation according to the reflector's length.

4.3.1 Optimization according to the reflector's length

4.3.1.1 LR = LPV/2

First, we considered a reflector with a length half the length of the PV module (Fig. 8). The process described above is performed considering a θR that varies between −10° and 45° and a θtilt between 26.7° and 79°. The optimum results obtained are listed in Table 3.

As shown in Table 3, forLR = LPV/2, the maximum average of POAMir is obtained by computing the POAMir average values for each θtilt,θR combination. This process is repeated for each month. The best combination values of θtilt and θR leading to the maximum average of POAMir irradiance are listed in Table 3. From Tables 1 and 3, a comparison between the plane of array irradiations without vs with reflectors is performed in order to evaluate the system's efficiency. Thus, the gain added by the planar reflectors was computed for each month.

The first step of the optimization strategy consisted on fixing the reflector's length compared to that of the PV module. Then, for each possible combination of ( θtilt, θR) calculating the ratio between the average POA irradiation obtained and the maximal average POA irradiation found over a month (Fig. 11).

Therefore, as shown in Figures 11a and 11b, the red area corresponds to the maximumPOA irradiance, from which we have defined our optimal inclination angles for each month. It is interesting to observe that, for both cases in Figure 11, there is much more sensitivity of POA irradiance to θR than to θtilt. That is, changes of this latter around the maximum POA irradiance would suppose a small loss, typically less than 10%, as shown in Figure 11.

Table 3

Optimal geometrical results corresponding to the POA max for each month with LR = LPV/2.

thumbnail Fig. 10

Comparison between the POA irradiance with vs. without reflectors for (a) December 2017; (b) February 2018.

thumbnail Fig. 11

Ratio between POA and POA (max) irradiances for each (θtilt, θR) combination over (a) December 2017; (b) February 2018.

thumbnail Fig. 12

Comparison between the POA irradiance with vs. without reflectors for (a) March 2018; (b) February 2018.

4.3.1.2 LR = LPV

Here, we considered a reflector with a length equal to the length of the PV module. We repeated the same calculation process and the optimum geometrical results obtained in this case are listed in Table 4.

ForLR = LPV, the best combination values of θtilt and θR leading to the maximum average of POAMir irradiation are listed in Table 4. From Tables 1 and 4, a comparison between the plane of array irradiances without vs with reflectors is performed in order to evaluate the system's efficiency.

Table 4

Optimal geometrical results corresponding to the POA max for each month with LR = LPV.

4.3.1.3 LR = 2 × LPV

Finally, we considered a reflector with LR = 2 × LPV. The optimal geometrical results obtained are listed in Table 5.

From Tables 1 and 5, the GM was computed as well in order to evaluate the system's efficiency. Figure 13 illustrates the comparison between the POA irradiance with vs without reflectors for three months from different seasons: summer (a), winter (b) and spring (c).

As shown in Figure 14, for a maximum GM in winter (a) where the Sun is at low elevation angles, the optimum array tilt angle increases. This variation will be in the opposite direction at summer where the sun reaches its highest elevation in June (b). We can observe as well the transitory optimal angles variation phase in spring (c). On the other hand, lowering the mirrors is of a great advantage in winter so we can get a maximum benefit from the diffuse irradiance during cloudy sky conditions. Figure 14 also shows that we are more restricted in the θ R variation, as it was also the case for Figure 11 for LR = LPV/2.

Table 5

Optimal geometrical results corresponding to the POA max for each month with LR = 2 × LPV.

thumbnail Fig. 13

Comparison between POA irradiance with vs. without reflectors, June (a), December (b) and April (c) for the case LR = 2 × LPV.

thumbnail Fig. 14

Ratio between POA and POA (max) irradiances for each angles combination (θtilt, θR) for December (a), June (b) and April (c).

4.3.1.4 Discussions and analysis

The GM varies between 5.1% (December 2017) and 11.9% (February 2018) for LR = LPV/2, between 13.1% (March 2018) and 22.7% (February 2018) for LR = LPV and between 21.9% (March 2018) and 36.0% (February 2018) for LR = 2 × LPV as illustrated respectively in Figures 10, 12 and 13. For all reflectors lengths, the energy yield reached minimum values in December and maximum values in June characterized by the highest direct normal irradiances. For the particular duration studied, E varied between 978 and 8648 Wh/m2. The obtained gain in POA irradiation added by the flat reflectors over the year was 8.5%, 18.0% and 28.7% corresponding respectively to LR = LPV/2, LR = LPV and LR = 2 × LPV architectures. Thus, comparing GA between LR = LPV/2 and LR = LPV, we can deduce a ΔG of 9.5% for the architecture with LR = LPV. Referring to the previous parts, we can say that for LR = 2 × LPV the average GM has increased significantly for each month. Therefore, comparing GA between the architecture LR = LPV and LR = 2 × LPV, we can deduce a ΔG of 10.7% for the architecture with LR = 2 × LPV.

Thus, at the end of this part, we can definitely say that the geometrical architecture design highly affects the efficiency of such system. The results obtained can highlight the importance of the flat reflectors length in order to achieve the higher incident POA irradiation. We found that an increase in the mirrors length was increasing the average outcome.

4.3.2 According to the angular variation

In this part, the optimization variable considered is the angular variation frequency for a fixed reflector's length. Thus, we first set LR  = LPV /2 and computed the optimal θtilt and θR combination considering: a monthly angular variation, a seasonal angular variation and a fixed architecture (constant θtilt and θR over the entire period). We computed the GM for each month as well as GA for each variation at the end of the optimization process. The same procedure was repeated for LR fixed to LPV and finally to 2 × LPV .

Figures 15 and 16 representing optimum θtilt and θR values show that during winter, it is more efficient to increase the PV array tilt angle and lower the reflector which is normal since the sun elevation is low as explained previously. It is the opposite case during summer. In addition, the annual variation cycles for θtilt and θR vary in opposite directions.

As highlighted in Figure 15, the longer the mirror is, it is better to straighten the PV in order to increase the GA (to achieve the maximal outcome from the reflected rays of the mirrors).

As illustrated in Figure 17 representing the GA evolution compared to a PV installation without reflectors, the POA irradiation gain doubles from LR = LPV/2 to LR = LPV for a monthly and seasonal varied architectures and triples for the fixed one. Nevertheless, it is not the same variation behavior going from LR = LPV to LR = 2 × LPV where the gain increasing ratio is lower. In fact, the larger we extend the length of the mirrors beyond the PV module length, the shading effect increases on one hand and there will be a part of the mirror's surface reflecting rays that won't be absorbed by the PV arrays on the other hand, which justifies that result. Actually, it is well shown in Table 2 and Figure 9 that when making LR larger, the gain increase gets lower. Considering LR = LPV, we can notice a ΔG of 6% from the seasonal to the monthly varying architectures and we can observe the same ΔG going from the fixed to the seasonal varying architecture.

Furthermore, we compared the annual gain between angular adjustment frequencies of PV-reflectors installations. According to the results obtained, a monthly-varied architecture has significant advantage over seasonal varied and fixed ones increasing the annual gain to 28.2% and 31.6% respectively. On the other hand, a seasonal varied architecture impact isn't much valuable over a fixed architecture with a 2.6% added annual gain. Nevertheless, it's important to mention that these obtained results depend on our specific case study including the weather conditions that characterized the period between June 2017 and June 2018 in Palaiseau. Thus, the obtained results cannot be completely generalized and an accurate study depending on each site must be performed in order to adopt the most efficient PV-reflector system.

Therefore, the best geometrical optimization of such an installation will depend on several factors such as geographical conditions and the accessibility to the installation allowing an adequate angular variation as well as several economic constraints.

thumbnail Fig. 15

Optimum θtilt over the year for (a) a monthly varied architecture; (b) a seasonal varied architecture; (c) a fixed architecture.

thumbnail Fig. 16

Optimum θR over the year for (a) a monthly varied architecture; (b) a seasonal varied architecture; (c) a fixed architecture.

thumbnail Fig. 17

Gain variation according to the reflector's length over the year for (a) a monthly varied architecture; Gain variation according to the reflector's length over the year for (b) a seasonal varied architecture; (c) a fixed architecture.

5 Conclusion

In this paper, a plane of array irradiance estimation model was developed and validated experimentally via our platform installed at SIRTA observatory in the case of a classical PV installation system as well as in case of an installation equipped with flat reflectors. The modelling simulation results were compared to measurements over two periods with and without reflector. During the considered 13 months, the mean absolute errors obtained were 6% and 7% for a classical PV system and a PV-reflector system respectively. Mean bias error values were lower than 1% in both cases.

Furthermore, an architectural optimization process was developed through this POA irradiance estimation model. A simulation analysis has been presented for all months over a year in order to find the geometrical parameter's combination (θtilt, θR and LR) insuring the higher POA incident irradiation on the PV array. The simulation results showed that the length of the mirrors highly affects the efficiency and performances of the PV-Reflector system. In fact, the annual gain increased from 8.5% to 28.7% when going from LR = LPV/2 to LR = 2 × LPV compared to a monthly-optimized installation without mirrors. Nevertheless, depending on each installation dimensional requirements, many construction constraints must be taken into consideration and the gain in irradiance doesn't vary in a proportional way with the length of the mirrors. This is because of the shading effect resulting with an activation of bypass diodes and because of the part of the reflected rays that won't reach the PV module as well.

The second part of our geometrical optimization process consisted on fixing the reflector's length and evaluating our system's applicability according to a monthly or a seasonal angular variation or a fixed PV-reflector architecture. The results obtained in this part showed that for our case study, a monthly-varied architecture is the most advantageous option with a 28.2 and 31.6% increasing in annual gain compared to a seasonal varied and fixed one respectively. Thus, in the presented case, for a small PV installation with an adjustable structure, it won't be difficult to adjust the inclination angles manually every month without additional costs. Nevertheless, a system's performance assessment should be conducted separately for each case study and location depending on the geographical, technical and economic aspects. Limitations regarding the available space and inter-row distance if we have an installation with several PV modules rows must be considered as well.

Regarding the economical evaluation: we performed a study on a type of reflector, similar to aluminium foils costing around 1 euro per m2 and the experimental performance results we obtained were satisfying. It's important to mention here that this gain in irradiance will vary with geographical locations. For instance, we conducted a further study where we found that the annual gain in POA irradiance could reach 35% in Athens, thus increasing the economic advantage of such a system.

Finally, a deeper optimization process will be conducted taking additional system's aspects and properties into consideration such as mirror's nonlinear reflectivity factor depending on the materials characteristics. An optimized electrical power output estimation considering the non-uniform illumination brought by such installation on the PV array will be presented in a future work. For that purpose, an experimental platform is under construction at GeePs laboratory in order to test our optimization results for the different geometrical configurations of PV-reflector architectures.

Nomenclature

AOI: Angle of incidence of the Sun rays on the PV module (°)

AOIR,PV : Angle of incidence of the reflected beam to the PV module (°)

AOIR : Angle of incidence of the Sun rays on the reflector (°)

BHI: Beam Horizontal Irradiance (W/m2)

BNI: Beam Normal Irradiance (W/m2)

CPV: concentrator photovoltaic

DHI: Diffuse Horizontal Irradiance (W/m2)

DRBI: Direct reflected beam irradiance (W/m2)

DPSR: Diffuse reflected solar radiation (W/m2)

E: Solar Irradiation (Wh/m2)

GA : Annual gain in POA irradiance (%)

GM : Monthly gain in POA irradiance added by the reflectors (%)

GHI: Global Horizontal Irradiance (W/m2)

GRISR: Ground reflected incident solar radiation (W/m2)

LPV : Photovoltaic array length (m)

LR : Reflector Length (m)

MAE: Mean absolute error

MBE: Mean bias error (W/m2)

POA: Plane of array irradiance per month (W/m2)

POAyear : Plane of array irradiance per year (W/m2)

POAMir : Plane of array irradiance with mirrors (W/m2)

R: Reflectivity of the mirrors

RMAE: Relative mean absolute error

RMBE: Relative mean bias error

VFPVR : View Factor from the PV module to the reflector

VFRPV : View Factor from the Reflector to the PV module

θa : Solar Azimuth angle (°)

θa,array : Azimuth array angle (°)

θel : Sun Elevation angle (°)

θPV,R : Angle between the PV module and the reflector (°)

θR : Angle between the reflector and the horizontal plane (°)

θtilt : Inclination angle of the PV module to the horizontal plane (°)

θZ : Solar zenith angle (°)

ρg: Ground reflectance (albedo), it represents a part of the reflected radiation

ΔG : The gain difference issued from an optimization procedure (%)

Acknowledgments

This work was partly supported by the TREND-X research program on energy transition of Ecole Polytechnique.

References

  1. C. Abdel Nour, A. Migan-Dubois, J. Badosa, V. Bourdin, C. Marchand, T. Akiki, Etude de l'effet du sur-éclairement non uniforme sur les performances d'une installation photovoltaïque équipée de réflecteurs plans, in JNPV, Dourdan, France, 2017 [Google Scholar]
  2. M. Pavlov et al., IEEE Journal of Photovoltaics 5, 1686 (2015) [CrossRef] [Google Scholar]
  3. J. Gelegenis, P. Axaopoulos, S. Misailidis, G. Giannakidis, M. Samarakou, B. Bonaros, Feasibility for the use of flat booster reflectors in various photovoltaic installations, Int. J. Renew. Energy Res. 5 , 82 (2015) [Google Scholar]
  4. J. Badosa et al., Deployment of a multi-technology photovoltaic module test bench on the SIRTA meteorological and climate observatory, in 31st European PV Solar Energy Conference and Exhibition (Eu-PVSEC), Hambourg (Germany), September 2015 [Google Scholar]
  5. EU Solar Market Grows 36% in 2018. SolarPower Europe (blog). Available at: http://www.solarpowereurope.org/eu-solar-market-grows-36-in-2018/ Accessed March 6, 2019 [Google Scholar]
  6. M. Rönnelid, B. Karlsson, P. Krohn, J. Wennerberg, Booster reflectors for PV modules in Sweden, Prog. Photovoltaics 8 , 279 (2000) [CrossRef] [Google Scholar]
  7. M. Boyd, Analytical model for solar irradiance near a planar vertical diffuse reflector − formulation, validation, and simulations, Solar Energy 91 , 79 (2013) [CrossRef] [Google Scholar]
  8. W. Andrews, Rob, A. Pollard, J. Pearce, Photovoltaic system performance enhancement with non-tracking planar concentrators: experimental results and BDRF based modeling, in Conference Record of the IEEE Photovoltaic Specialists Conference, 2013. https://doi.org/10.1109/PVSC.2013.6744136 [Google Scholar]
  9. M. Haeffelin, L. Barthès, O. Bock, C. Boitel, S. Bony, D. Bouniol, P. Drobinski, SIRTA, a ground-based atmospheric observatory for cloud and aerosol research, Ann. Geophys. 23 , 253 (2005) [Google Scholar]
  10. BSRN, http://bsrn.awi.de [Google Scholar]
  11. C. Abdel Nour et al., Photovoltaic system equipped with flat reflectors: new MPPT model in case of non-uniform illumination on PV modules, in 35th European PV Solar Energy Conference and Exhibition (Eu-PVSEC), Brussels, Belgium, September 2018 [Google Scholar]
  12. J.A. Duffie, W.A. Beckman, Solar Engineering of Thermal Processes, 4th edn. (Wiley, 2013). https://www.wiley.com/en-cu/Solar [CrossRef] [Google Scholar]

1

© SolarPower Europe 2019.

Cite this article as: Christine Abdel Nour, Anne Migan-Dubois, Jordi Badosa, Vincent Bourdin, Claude Marchand, Tilda Akiki, Geometrical optimization for a photovoltaic installation equipped with flat reflectors based on plane of array estimations, EPJ Photovoltaics 11, 1 (2020)

All Tables

Table 1

Optimal θtilt corresponding to the POA max of each month for a classical installation.

Table 2

GA variation according to the reflector's length.

Table 3

Optimal geometrical results corresponding to the POA max for each month with LR = LPV/2.

Table 4

Optimal geometrical results corresponding to the POA max for each month with LR = LPV.

Table 5

Optimal geometrical results corresponding to the POA max for each month with LR = 2 × LPV.

All Figures

thumbnail Fig. 1

Irradiances characterizing a classical PV system architecture (a) and a PV-reflector system architecture (b).

In the text
thumbnail Fig. 2

Direct, diffuse and global irradiances measurement sensors, SIRTA observatory, which are part of the PAL station of the Baseline Surface Radiation Network (BSRN, https://bsrn.awi.de/).

In the text
thumbnail Fig. 3

Estimation of the plane of array irradiance according to the reflector: reflected irradiance reaching the highest level (a), reflected irradiance is below the highest level of the PV module (b) and causing total or partial shading on the PV module (c).

In the text
thumbnail Fig. 4

Characterization test bench equipped with sensors and flat reflectors, SIRTA observatory.

In the text
thumbnail Fig. 5

Comparison between the measured and modelled POA irradiance over the period from October 13th 2017 to June 8th 2018: Installation without flat reflectors.

In the text
thumbnail Fig. 6

POA measured vs. POA modelled irradiances (September 2017 to October 2017).

In the text
thumbnail Fig. 7

Comparison between the POA irradiance with and without reflector from 1st June 2017 to 8th of June 2018.

In the text
thumbnail Fig. 8

Experimental platform characterized by LR, LPV, θtilt and θR.

In the text
thumbnail Fig. 9

GA variation according to the reflector's length for a monthly varied, seasonal varied and a fixed architecture.

In the text
thumbnail Fig. 10

Comparison between the POA irradiance with vs. without reflectors for (a) December 2017; (b) February 2018.

In the text
thumbnail Fig. 11

Ratio between POA and POA (max) irradiances for each (θtilt, θR) combination over (a) December 2017; (b) February 2018.

In the text
thumbnail Fig. 12

Comparison between the POA irradiance with vs. without reflectors for (a) March 2018; (b) February 2018.

In the text
thumbnail Fig. 13

Comparison between POA irradiance with vs. without reflectors, June (a), December (b) and April (c) for the case LR = 2 × LPV.

In the text
thumbnail Fig. 14

Ratio between POA and POA (max) irradiances for each angles combination (θtilt, θR) for December (a), June (b) and April (c).

In the text
thumbnail Fig. 15

Optimum θtilt over the year for (a) a monthly varied architecture; (b) a seasonal varied architecture; (c) a fixed architecture.

In the text
thumbnail Fig. 16

Optimum θR over the year for (a) a monthly varied architecture; (b) a seasonal varied architecture; (c) a fixed architecture.

In the text
thumbnail Fig. 17

Gain variation according to the reflector's length over the year for (a) a monthly varied architecture; Gain variation according to the reflector's length over the year for (b) a seasonal varied architecture; (c) a fixed architecture.

In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.