Table 1
Summary of defective modules in this study.
| Defect type | # of modules | Range of power loss [%] | Module type | Details |
|---|---|---|---|---|
| Cell cracks | 8 | 4−5% | • Monofacial PERC 305 W | Cells cracked by mechanical stress test. Total of 69 cells affected. |
| Cell interconnections | 8 | 3−14% | • Monofacial PERC 305 W | Cell ribbon interconnection cut from the back sheet. Total of 98 cells affected. |
| PID | 6 | 5% | • Monofacial PERC 305 W | PID stress tested according to standard |
| Short-circuited bypass diode | 7 | 33−66% | • Monofacial PERC 305 W • Bifacial PERC 295 W • Bifacial PERC 540 W (Half-cut cells) |
4 modules with 1 Shorted diode and 3 with 2 Shorted diodes |
| Glass crack | 2 | <1% | • Bifacial PERC 540 W (Half-cut cells) | Glass cracked in front and rear side |
| Soiling 1 | 6 | 33% | • Monofacial PERC 305 W • Bifacial PERC 295 W • Bifacial PERC 540 W (Half-cut cells) |
Punctual soiling − Bird drops |
| Soiling 2 | 6 | 66% | • Monofacial PERC 305 W • Bifacial PERC 295 W • Bifacial PERC 540 W (Half-cut cells) |
Large area soiling − Sand |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.
