Table 1

Summary of defective modules in this study.

Defect type # of modules Range of power loss [%] Module type Details
Cell cracks 8 4−5% • Monofacial PERC 305 W Cells cracked by mechanical stress test. Total of 69 cells affected.
Cell interconnections 8 3−14% • Monofacial PERC 305 W Cell ribbon interconnection cut from the back sheet. Total of 98 cells affected.
PID 6 5% • Monofacial PERC 305 W PID stress tested according to standard
Short-circuited bypass diode 7 33−66% • Monofacial PERC 305 W
• Bifacial PERC 295 W
• Bifacial PERC 540 W (Half-cut cells)
4 modules with 1 Shorted diode and 3 with 2 Shorted diodes
Glass crack 2 <1% • Bifacial PERC 540 W (Half-cut cells) Glass cracked in front and rear side
Soiling 1 6 33% • Monofacial PERC 305 W
• Bifacial PERC 295 W
• Bifacial PERC 540 W (Half-cut cells)
Punctual soiling − Bird drops
Soiling 2 6 66% • Monofacial PERC 305 W
• Bifacial PERC 295 W
• Bifacial PERC 540 W (Half-cut cells)
Large area soiling − Sand