Table 4

List of implemented and analyzed failure in TFV1 and relative records analyzed.

Failure type Acronym Number of records labeled with faults Period of monitoring
Normal Operation − No Failure in the PV String NO 427,078 From: 01/07/2023
To: 31/07/2024
Two Diode Fault 2DSC 35,265  
Four Diode Fault 4DSC 31,470  
Eight Diode Fault 8DSC 39,604  
Increased Series Resistance @1Ω RS1Ω 23,804  
Increased Series Resistance @2Ω RS2Ω 19,502  
Increased Series Resistance @3Ω RS3Ω 10,980 Total days: 395
Two Modules in Partial shading, with 25% cell area covered 2M-PS25 7,086  
Four Modules in Partial shading, with 25% cell area covered 4M-PS25 7,319  
TOTALS 602,108  