Table 3
List of implemented and analyzed failure in TFV3 and relative records analyzed.
Failure type | Acronym | Number of records labeled with faults | Period of monitoring |
---|---|---|---|
Normal Operation − No Failure in the PV String | NO | 9,180 | From: 13/06/2024 To: 02/09/2024 |
Four Diode Fault | 4DSC | 7,875 | |
Increased Series Resistance @ 5Ω | RS5Ω | 10,441 | |
Four Modules in Partial shading, with 50% cell area covered | 4M-PS50 | 11,522 | |
Four Diode Fault + Four Modules in Partial shading, with 50% cell area covered | 4DSC+ 4M-PS50 | 14,634 | Total days: 81 |
Four Diode Fault + Increased Series Resistance @ 5Ω | 4DSC+RS5Ω | 11,932 | |
Increased Series Resistance @ 5Ω + Four Modules in Partial shading, with 50% cell area covered | RS5Ω +4M-PS50 | 6,240 | |
TOTALS | 71,824 |