Comparison of the experimental findings with other literature in standard conditions.
Authors | Coolant | Temperature reduction (°C) | Increase in output power |
---|---|---|---|
[38] Ismail et al.,(2023) | Porous media | 20.2 | 9.4 |
[38] Ismail et al.,(2023) | Porous media | 46 (indoor) | 50 |
[39] Ismail et al.,(2021) | Nano-Fluid | 50 (indoor) | 60 |
[40] Lin et al., (2019) | Air | 4 | 7 |
[41] Micheli et al., (2015) | Air | 13 | 7.7 |
[42] Moradgholi et al., (2014) | Methanol | 13 | 5 |
[43] Smith et al., (2014) | Water | 11 | 6 |
[44] Hasan et al., (2016) | PCM | 10 | 6.6 |
[45] Tang et al., (2010) | Air | 4.7 | 8 |
[30] Ebaid et al., (2018) | Nano-Fluid | 20 | 9 |
[46] El Mays et al., (2017) | Air | 6 | – |
[19] Mazón-Hernández et al., (2013) | Air | 22 | – |
[47] Wu et al., (2018) | Air | 12.5 | – |
[48] Ebrahimi et al., (2015) | Air | 20 | |
[49] Amori and Al-Najjar, (2012) | Air | 16 | |
[50] Herez et al., 2020 | Heat pipe cooling | 14 | – |
[51] Karami & Rahimi, (2014) | Nano-Fluid | 18 | |
[52] Al-Musawi et al., (2019) | Nano-Fluid | 19 | |
[53] Bahaidarah et al., (2013) | Water | 17 | – |
[54] Rahimi et al., (2014) | Water | 26 | – |
[10] Nižetić et al., (2016) | Water | 26 | – |
[55] Baloch et al., (2015) | Water | 12 | – |
[56] Hachicha et al., (2015) | Water | 7.7 | – |
[57] Irwan et al., (2015) | Water | 15 | – |
[58] Wu & Xioang, (2014) | Water | 18.5 | – |
[59] Barrau et al., (2011) | Water | 2 | – |